18.8. The STK5 Data Record – Stokes Fifth Order Wave

This data record tells the program to use the Stokes fifth order wave as an incident wave instead of the Stokes second order wave, which is used by default in the calculation of the Froude-Krylov forces. A set of three additional wave parameters is defined in this record.

     2   5  7   11    16    21        31        41       51
    - --- -- ---- ----- ----- --------- --------- ---------
   |X|   |  |STK5|     |XXXXX|         |         |        |
    - --- -- ---- ----- ----- --------- --------- ---------
       |  |   |     |             |         |         |
       |  |   |     |             |-----------------
       |  |   |     |             |
       |  |   |     |             |_ (3) values of wave parameters (3F10.0) 
       |  |   |     |
       |  |   |     |_(2) Set number of input parameters (I5)
       |  |   |
       |  |   |_(1) Compulsory Data Record Keyword (A4)
       |  |
       |  |_Optional User Identifier (A2)
       |
       |_Compulsory END on Last Data Record in Data Category (A3)
  1. The data record keyword defines the Stokes fifth order wave.

  2. The sequence number of the set of the additional Stokes fifth order wave parameters among five sets of input parameters.

  3. Three parameters of the specified set.

Set NumberParameter 1Parameter 2Parameter 3
1WavelengthStill water depthUniform current
2Wave periodStill water depthUniform current
3WavelengthMean water depthUniform current
4WavelengthStill water depthVolume flux
5Wave periodStill water depthVolume flux