This data record tells the program to use the Stokes fifth order wave as an incident wave instead of the Stokes second order wave, which is used by default in the calculation of the Froude-Krylov forces. A set of three additional wave parameters is defined in this record.
2 5 7 11 16 21 31 41 51 - --- -- ---- ----- ----- --------- --------- --------- |X| | |STK5| |XXXXX| | | | - --- -- ---- ----- ----- --------- --------- --------- | | | | | | | | | | | |----------------- | | | | | | | | | |_ (3) values of wave parameters (3F10.0) | | | | | | | |_(2) Set number of input parameters (I5) | | | | | |_(1) Compulsory Data Record Keyword (A4) | | | |_Optional User Identifier (A2) | |_Compulsory END on Last Data Record in Data Category (A3)
The data record keyword defines the Stokes fifth order wave.
The sequence number of the set of the additional Stokes fifth order wave parameters among five sets of input parameters.
Three parameters of the specified set.
Set Number | Parameter 1 | Parameter 2 | Parameter 3 |
1 | Wavelength | Still water depth | Uniform current |
2 | Wave period | Still water depth | Uniform current |
3 | Wavelength | Mean water depth | Uniform current |
4 | Wavelength | Still water depth | Volume flux |
5 | Wave period | Still water depth | Volume flux |