Performing a Multi-Sensors Light Expert Analysis

The following procedure helps you perform a light expert analysis on several sensors at the same time.

To perform a Multi-Sensors Light Expert Analysis:

  1. Create a Light Expert Group.
  2. Create a Direct simulation.
  3. In the General section, set Light Expert to True.

  4. Add the Light Expert Group to the Sensors list of the simulation.

    As Light Expert is set to True, the LXP check box is of the Light Expert Group is automatically activated.

    Note: Only one Light Expert Group can be added to the simulation.
  5. Define the LPF max path.

    We recommend you to set a LPF max path parameter equivalent to the number of rays propagated in the system. Otherwise, when LPF max path is much more smaller than the number of rays, information will not be integrated in the analysis.

    Warning: The *.lpf file size increases with the number of rays interaction. The more interactions in the system, the bigger the *.lpf file size. To avoid such situation, you can create small sensor (not a lot of pixel) to cover the area on which you want to perform the Light Expert analysis with the *.lpf file.
  6. Run the simulation.
  7. To visualize and analyze the result, double-click the *.lpf file.
    The Light Expert opens as well as each XMP map generated for each sensor of the Light Expert Group.