Winding Feasibility

The following winding feasibility rules are applied to ensure that a winding is valid.

General rules:

Slots / Phases / ParallelPaths = Integer

Poles / ParallelPaths = Integer

Slots / Phases / t = Integer (t = Highest Common Factor between Poles / 2 and Slots)

Number of slot phasors: N_phasors = Slots / t (t = Highest Common Factor between Poles / 2 and Slots)

Angle between slot phasors: Delta = 360 x Poles / 2 / Slots

Additional rules for Single layer winding:

Slots = Even number

Coil pitch = Odd number

Additional rules for Concentric winding:

Slots / Poles / (2 x winding layers) = Integer

See also: Winding Pattern