Using Datasets to Define Temperature-Dependent Parameters

Some Icepak thermal boundary condition parameters can be assigned a temperature-dependent value using a dataset. For a complete list of temperature-dependent parameters, see Temperature-Dependent Thermal Properties. You can access the Add Dataset dialog two ways:

Note: Datasets you have previously created are available as options in the Variation drop-down list.

Defining a Dataset for Temperature-Dependent Parameters

  1. In the boundary condition or native component dialog box, enable the check box next to the parameter.
  2. Select Temp Dep from the drop-down list and click Edit.
  3. In the Advanced Time Variations dialog box, select Piecewise Linear from the Time Variation Function drop-down list.
  4. Specify a value for S0, which is the total power value used during the simulation when the temperature is not in the range specified in the dataset.
  5. From the Variation drop-down list. select Edit.
  6. In the Datasets dialog box, click Add > 1D Dataset.
  7. In the Add Dataset dialog box, enter a Name.
  8. In the Coordinates area, click the X column header and select Temperature and then click it again and select a unit of temperature.
  9. Click the Y column header and select a parameter category (e.g., Power) and then click it again and select a unit for the parameters (e.g., W).
  10. In the X and Y columns enter the values for time and the time-dependent parameter.
  11. Click OK to save the dataset.
  12. In the Datasets dialog box, click Done.