Icepak Solve Setup Defaults

The Icepak Solve Setup Defaults drop-down list contains options that automatically define solution settings based on the selected simulation type.

The following sections detail which settings are defined for each simulation type.

Note:

The Solve Setup Defaults options restores all settings to the application defaults.

Forced Convection

Select Forced Convection Defaults if your simulation includes forced convection, in which fluid moves within the computational domain by a source (for example, a fan). The following solution settings are defined as forced convection defaults.

Note:

Forced Convection Defaults does not appear as an option if the Solution Type is set to Temperature Only. The settings automatically defined depend on the Solution Type.

Natural Convection

Select Natural Convection Defaults if your simulation includes natural convection, in which fluid moves within the computational domain by changes in the density of the fluid due to variations in temperature. The following solution settings are defined as natural convection defaults.

Note:

Natural Convection Defaults does not appear as an option if the Solution Type is set to Temperature Only or Flow Only.

Mixed Convection

Select Mixed Convection Defaults if your simulation includes forced convention and natural convection. The following solution settings are defined as mixed convection defaults.

Note:

Mixed Convection Defaults does not appear as an option if the Solution Type is set to Temperature Only or Flow Only.

Conduction Only

Select Conduction Only Defaults if your simulation includes only temperature analysis. The following solution settings are defined as conduction only defaults.

Note:

Conduction Only Defaults does not appear as an option if the Solution Type is set to Flow Only.

LTI ROM

Select LTI ROM Defaults if your transient simulation includes a parametric analysis intended for LTI ROM export. The following solution settings are defined as LTI ROM defaults.

Note:

When you select LTI ROM Defaults, a dataset with preset defaults is created and assigned to the piecewise constant variation function.

Related Topics:

The Icepak Solve Setup Dialog (Transient)