Continuing a Cosimulation with Maxwell

After a successful simulation, either to completion or clean-stopped, you can continue the simulation from the current end time.

To enable this possibility:

Start the analysis. Simulation can be extended this way as many times as desired.

Note:

If Maxwell is used non-interactively—that is, when you select the Save project after use check box—it shuts down after each simulation and results data is lost if not saved, so a KRN file cannot be used successfully.

If you select the Save project after use check box, the end time in the setup must be made greater before the KRN file is loaded or Twin Builder simulation will fail.

If KRN file save or load is set and the Maxwell project is not set to be saved the following error message displays:

“The Maxwell TR-TR coupling component is not set to save the Maxwell project, but saving or loading a state file has been specified. Maxwell results valid at the state file's end time will be necessary when using a state file.”

Note:

Unlike usage in a non-cosimulation setting, a specific Simulation State (KRN) file cannot be reused once Maxwell has results at a later time. Also, the Enable continue to solve option is ignored for cosimulation with Maxwell.