Solution Data for Three-Phase Induction Motors

To access the solution data, right-click Analysis in the project tree, and click Add Solution Setup.

The Solution Setup window contains the following fields:

Operation Type

On the General tab. The operation type is automatically set to Motor for this machine type.

Load Type

On the General tab. Select from Const Speed, Const Power, Const Torque, Linear Torque, and Fan Load. The default is Const Power.

Rated Output Power

On the General tab. Type a value for the rated output voltage, and select the units.

Rated Voltage

On the General tab. Type a value for the rated voltage, and select the units.

Rated Speed

On the General tab. Type a value for the rated speed, and select the units.

Operating Temperature

On the General tab. Type a value for the operating temperature, and select the units.

Frequency

On the Three-Phase Induction Motor tab. Type a value for the frequency, and select the units.

Winding Connection

On the Three-Phase Induction Motor tab. Select from Wye or Delta.

Related Topics 

Setting Up Analysis Parameters for a Three-Phase Induction Motor