Setting Up Analysis Parameters for a Three-Phase Induction Motor
To define the solution data:
- To open the Solution Setup window, right-click Analysis in the project tree, and click Add Solution Setup.
- Click the General tab. The Operation Type is automatically set to Motor for this machine type.
- Select the Load Type
used in the motor from the following options:
Const Speed
The speed remains constant in the motor.
Const Power
Const Torque
The torque remains constant regardless of the speed. In this case, Tload = Trated, given by the output power divided by the given rated speed.
Linear Torque
The torque increases linearly with speed. In this case, Tload = Trated * (n/nrated) where Trated is given by the output power divided by the given rated speed.
Fan Load
The load varies nonlinearly with speed. In this case, Tload = Trated * (n/nrated)2 where Trated is given by the output power divided by the given rated speed.
- Enter the output power developed at the shaft of the motor in the Rated Output Power field.
- Enter the RMS line-to-line voltage in the Rated Voltage field.
- Enter the desired rotor speed in the Rated Speed field. When input Rated Speed is less than the Synchronous Speed, the machine operates as a motor. When input Rated Speed is greater than the Synchronous Speed, the machine operates as a generator. For an induction generator, the rated performance will be calculated at the input Rated Speed with the three-phase windings connecting to infite bus.
- Enter the temperature at which the system functions in the Operating Temperature field.
- Click the Three-Phase Induction Motor tab.
- Enter the electrical line frequency in the Frequency field, and select the units.
- Select the Winding Connection from the following options:
- Wye (Y)
- Delta
- Click OK to close the Solution Setup window.
Related Topics
Solution Data for Three-Phase Induction Motors