Choosing a Variable to Tune

Before a variable can be tuned, you must specify that you intend for it to be tuned in the Properties window.

  1. If the variable is a design variable, click Maxwell 3D (or Maxwell 2D, or RMxprt) > Design Properties. You can also access the Design variables from a menu in the lower left corner of the following Optimization dialogs: Parametric, Optimization, Sensitivity, Statistical, Design of Experiments, and Design Xplorer Setup.
  2. If the variable is a project variable, click Project > Project Variables. You can also access the Project variables from a menu in the lower left corner of the following Optimization dialogs: Parametric, Optimization, Sensitivity, Statistical, Design of Experiments, and Design Xplorer Setup.

  3. Click Edit Variables and from the menu select Edit Design (or Project) Variables.

  4. The Properties window appears.

    Note: Dependent variables cannot be tuned.
  5. Select the Tuning option.
  6. For the variable you want to tune, select Include.
    Note: Complex numbers are not allowed for variables to be used in an Optimetrics sweep, or for optimization, statistical, sensitivity or tuning setups.
  7. Click OK.

The selected variable is now available for tuning in the Tune window.

Related Topics 

Tuning a Variable