Matl Command

Operates on the vector field quantity in the top register of the Fields Calculator based on a material property. At each tetrahedron, the field quantity is operated on by the value of the selected material property — taking the different material attributes of each object into account.

To operate on a vector quantity by a material property:

  1. Click Matl.

    The Material Operation window appears.

  2. Select a material property. Available properties are:
    .

    Permittivity (epsi)

    The permittivity, e.

    Permeability (mu)

    The permeability, m.

    Conductivity

    The conductivity, s.

    Omega (w)

    The angular frequency, w. The angular frequency is equal to 2pf, where f is the frequency at which the solution was generated.

    MassDensity

    This is based on the value of the Mass Density material property. MassDensity is treated like a named expression. Selecting MassDensity disables the Operation radio buttons for Multiply or Divide in the Material Operations dialog box.


  3. For Permittivity, Permeability, Conductivity or Omega, select an operation — Multiply or Divide. Selecting MassDensity disables these operations. The MassDensity scalar can be used like any other named expression.
  4. Choose OK to operate on the field quantity by a material property or Cancel to stop the operation. If you selected MassDensity and click OK, a scalar named expression MassDensity is pushed onto the stack.