The Reevaluate system is a parametric system that collects all available designs with the help of design directories and a monitoring database file. All nodes within the system (for example, integration nodes as solver) should be executed in read mode if available.
Reevaluation Settings
To access the options shown in the following table, double-click the Reevaluate system on the Scenery pane and switch to the Reevaluation settings tab.
Option | Description |
---|---|
Path to design directories | Browse for the corresponding design directories. |
Design directory format |
Modifies the design directory format. Default format is Design%04d. Any format containing a placeholder for integer numbers is valid. Integers are represented by %d, %i, %x or %o. For multiple numbers, use %1%. Some examples are:
|
Design numbers | Defines the range of design numbers using all, [, -, ] or ;. By default, all found design directories within the selected path are set. The design numbers do not have to be consecutive, for example [1-3];5;[7-10]. Leaving this line empty means using all designs. |
Merge data | Selecting this check box displays the following options.
|
Type of postprocessing | Sets the type of resulting sampling monitoring database file. |
Adapt bounds | When selected, the bounds of the parameters are set to the minimum and maximum values of the sampling for Sensitivity monitoring database files. |
Write optiSLang post-processor database file | Select how often the post-processor database file is written. |
Show as soon as available | When selected, show postprocessing during the run as soon as it is available or after a certain number of designs. |
Show on termination | When selected, the postprocessing opens after the algorithm terminates. An additional Postprocessing node is not required. |
Register files | When selected, defines file filter rules. Any file matching
the defined filters is registered.
|
Additional Options
This algorithm allows Additional Options.