3.12. Set ASCII Time History Outputs

  1. Select ASCII_option from the list.

  2. Click Edit.

  3. Enter Default DT=0.1 in the Keyword Input Form popup .

  4. Activate GLSTAT (global statistics).

  5. Activate MATSUM (material energy summary).

  6. Activate RWFORC (rigidwall force).

  7. Activate SWFORC (spotweld force).

  8. Click Accept.