Scope |
Scoping Method, options include: Geometry Selection: Default setting, indicating that
the condition is applied to a geometry or geometries, which are chosen using a
graphical selection tools. Named Selection: Indicates that the geometry
selection is defined by a Named Selection.
You may wish to review the Mechanical APDL References and
Notes at the bottom of the page for specific command execution
information regarding these selections.
|
Definition |
Criterion: Options included
and .
- Energy
If is selected, you need to enter an
Energy Coefficient. Energy Coefficient: This criterion checks the
strain energy of any element that is part of the defined component using the
following calculation. A component is defined as the assembly of all scoped
elements. where: Ee = strain energy of single target
element. c1 = user input energy coefficient. Etotal = total strain energy of the
component. NUME = number of elements of the component.
If this criterion is satisfied at an element, the program refines the
element. A smaller Energy Coefficient improves the
potential to trigger the mesh regeneration for the same loads. - Box
If is selected, the following additional
properties require entries: Coordinate System (default is
): defines the
minimum values of the box. Length X: defines the diagonal length on global
X axis. Length Y: defines the diagonal length on global
Y axis. Length Z (for 3D): defines the diagonal length
on global Z axis.
All the following common criteria properties are available for all
Criterion property options as well as 2D analyses: Check At: Options included or . Value: This property further defines the
Check At property. The default value is
1 . Time Range: options included or . When specified as
, you need to enter a and . The
value must be larger than the
value.
Suppressed: Include ( -
default) or exclude () the condition.
|