You import an Imported CFD Pressure through External Data from a CFD General Notation System (.cgns) source file. This imported loading condition is only supported for Coupled Field Harmonic, Harmonic Acoustics, and Harmonic Response analyses. See the Imported Boundary Conditions section for the general workflow for importing loading conditions. This load enables you to specify the mapping settings and review the mapping results.
Limitation: This load does not currently support the Named Selection Creation category properties.
See the Imported Load (Group) object reference page for a complete listing and descriptions for all properties of this object.
Default Settings for Imported CFD Pressure
Note the following specific property settings for the Imported CFD Pressure:
Applied By: Read-only and automatically set to .
Loaded Area: Read-only and automatically set to .
Mapped Data: Read-only and automatically set to .
Source Zone: This property provides a drop-down list of all source zones defined in the source file. The default setting is .
Mapping Settings
Note the following specific property settings for the Settings and Advanced categories of the Details pane:
Weighting: Only the option (mapping algorithm) is supported for this property.
Outside Option: The default setting for this property is .
Number of Points: The default setting for this property is 2.