This option will prevent a solver from executing, however all files required for
execution will be written to the run directory, including the script
.solvercmd. This script must then be launched manually by you.
The graphical interface will show the execution log and update the convergence graphs
until the Stop → Kill button is
pressed.
This queue is useful when the .solvercmd must be edited manually
before it is launched, or when the .solvercmd script is executed on
a machine other than the computer where FENSAP-ICE is running.
On Windows, the .solvercmd script must be launched as an argument
to nti_sh.exe (provided in $NTI_PATH).