Selecting the Automatic with Value option allows the CFX-Solver
to automatically read the initial conditions from an initial values file if it can
find one, or else use the specified value or expression. This option is often better
than using the Automatic method (assuming a sensible value is
set), and is almost always required for compressible flow cases.