2 5 7 16
- --- -- ---- ---- ----
|X| | |PTST|XXXX| |
- --- -- ---- ---- ----
| | | |
| | | |_(1) Tether Number (I5)
| | |
| | |_Compulsory Data Record Keyword (A4)
| |
| |_Optional User Identifier (A2)
|
|_Compulsory END on last data record in data category (A3)
(1) The tether number designates statistic results of nodal motions, nodal/element force response along the defined tether to be printed in the listing file for Aqwa-Drift only. If the tether number is omitted, the results are output for all tethers.
Note: This data record will be ignored if The PTRT Data Record - Print Tether Nodal/Element Responses is not defined.