Vista CCM

Vista CCM
This container holds Analysis data for an instance of Vista CCM.

Methods

Edit

This command class launches the Vista popup GUI.


GetVistaCCMBladeDesignProperties

This query takes a container reference and returns the Data Entity which contains user settings and properties for the VistaCCD Performance Map container.

Return     Reference to the requested Data Entity
    Type     DataReference

Data Entities

VistaCCMBladeDesign

Setup represents a VistaCCM project definition.

Properties

Alpha3

Inlet angle

Type     Quantity
Read Only    No
B5

User input: impeller tip width

Type     Quantity
Read Only    No
BetaBlade5

User input: impeller blade exit angle

Type     Quantity
Read Only    No
BetaBladeLEhub

User input: hub vane angle at the leading edge

Type     Quantity
Read Only    No
BetaBladeLEshr

User input: shroud vane angle at the leading edge

Type     Quantity
Read Only    No
ConditionsFromUpstream

Flag to choose whether to update operating conditions from upstream cell or not

Type     bool
Read Only    No
D5

User input: impeller exit diameter

Type     Quantity
Read Only    No
DisplayText

The general property that defines the user-visible name of an entity. This property is defined for all data entities but is used only in those entities that present a label in the user interface.

Type     string
Read Only    No
DLEhub

User input: Hub diameter at the leading edge

Type     Quantity
Read Only    No
DLEshr

User input: shroud diameter at the leading edge

Type     Quantity
Read Only    No
EffPolyData

Results data: Range of polytropic efficiencies

Type     List<List<float>>
Read Only    No
EtaPoly

Polytropic efficiency

Type     float
Read Only    No
GammaUser

Ratio of specific heats

Type     float
Read Only    No
GasModel

Gas model

Type     int
Read Only    No
ImperialUnits

User input, Imperial units option

Type     bool
Read Only    No
KDiff

User input: Diffuser type (-1.0 = vaneless, 1.0 = vaned)

Type     float
Read Only    No
KType

User input: Machine type (-1.0 = process, 1.0 = turbocharger)

Type     float
Read Only    No
ListSpeed

Results data: Range of speeds

Type     List<float>
Read Only    No
Loading

Work factor

Type     float
Read Only    No
MachU5

Tip Mach number

Type     float
Read Only    No
MassFlow

Design point mass flow rate

Type     Quantity
Read Only    No
MassFlowData

Results data: Range of mass flow rates

Type     List<List<float>>
Read Only    No
NMain

User input: number of main vanes

Type     int
Read Only    No
NSpeeds

User input, number of speeds

Type     int
Read Only    No
NSplit

User input: number of splitter vanes

Type     int
Read Only    No
PIF

Power input factor

Type     float
Read Only    No
PresRatioData

Results data: Range of pressure ratios

Type     List<List<float>>
Read Only    No
PressureRatio

Design point pressure ratio

Type     float
Read Only    No
RUser

Gas constant

Type     Quantity
Read Only    No
SIunits

User input, SI units option

Type     bool
Read Only    No
SpeedMax

User input, maximum speed

Type     Quantity
Read Only    No
SpeedMaxFixed

User input, maximum speed

Type     Quantity
Read Only    No
SpeedMin

User input, minimum speed

Type     Quantity
Read Only    No
SpeedMinFixed

User input, minimum speed

Type     Quantity
Read Only    No
StagPressure

Inlet stagnation pressure

Type     Quantity
Read Only    No
StagPressureFixed

Inlet stagnation pressure

Type     Quantity
Read Only    No
StagTemp

Inlet stagnation temperature

Type     Quantity
Read Only    No
StagTempFixed

Inlet stagnation temperature

Type     Quantity
Read Only    No
SzrFlowCoeff

Flow coefficient

Type     float
Read Only    No
ThkHub

User input: Hub vane normal thickness

Type     Quantity
Read Only    No
ThkShr

User input: shroud vane normal thickness

Type     Quantity
Read Only    No
ThroatArea

User input: throat area

Type     Quantity
Read Only    No
TipMachInData

Results data: Range of inlet tip Mach numbers

Type     List<List<float>>
Read Only    No
TipMachOutData

Results data: Range of outlet tip Mach numbers

Type     List<List<float>>
Read Only    No
VistaCCMTitle

Editor Title

Type     string
Read Only    No