Evaluate Mapping Quality in the Transcript

In System Coupling's Outline of Schematic, click Solution | Solution Information | System Coupling so System Coupling's Transcript output is shown in the Solution Information pane.


Tip:  For cases run with System Coupling in Workbench, the co-simulation transcript is written to the scLog.scl file in System Coupling's working directory, \\dp0\SC\SC\SyC.


Review the Mapping Summary, which was generated at analysis initialization. The mapping diagnostics indicate that all target and source nodes were successfully mapped for both data transfers.

No further investigation of mapping is necessary

Figure 40: Mapping diagnostics at analysis initialization


+-----------------------------------------------------------------------------+
|                               MAPPING SUMMARY                               |
+-----------------------------------------------------------------------------+
|                                     |      Source            Target         |
+-----------------------------------------------------------------------------+
| CouplingInterface 1                 |                                       |
|   Force                             |                                       |
|     Mapped Area [%]                 |       100               100           |
|     Mapped Elements [%]             |       100               100           |
|     Mapped Nodes [%]                |       100               100           |
|   displacement                      |                                       |
|     Mapped Area [%]                 |       100               100           |
|     Mapped Elements [%]             |       100               100           |
|     Mapped Nodes [%]                |       100               100           |
+-----------------------------------------------------------------------------+



Note:  If you wish to verify, you can review the mapping for each data transfer when you open System Coupling's results in EnSight.