Evaluate Mapping Quality in the Transcript

Review the Mapping Summary that was written to System Coupling's Transcript at analysis initialization. It shows the following diagnostics:

No further investigation of mapping is necessary.

Figure 50: System Coupling's mapping diagnostics at analysis initialization


+-----------------------------------------------------------------------------+
|                               MAPPING SUMMARY                               |
+-----------------------------------------------------------------------------+
|                                     |      Source            Target         |
+-----------------------------------------------------------------------------+
| CouplingInterface 1                 |                                       |
|   Force                             |                                       |
|     Mapped Area [%]                 |       100               100           |
|     Mapped Elements [%]             |       100               100           |
|     Mapped Nodes [%]                |       100               100           |
|   Mesh_Displacement                 |                                       |
|     Mapped Area [%]                 |       100               100           |
|     Mapped Elements [%]             |       100               100           |
|     Mapped Nodes [%]                |       100               100           |
+-----------------------------------------------------------------------------+



Note:  If you wish to verify, you can open the results in EnSight and review the mapping for each data transfer.