These are the text commands available for using parametric studies:
- parametric-study/
- Enter the parametric study menu. 
- parametric-study/design-points/
- Enter the design point menu for a parametric study. - parametric-study/design-points/add
- Adds the design point to the parametric study. 
- parametric-study/design-points/auto-create/
- Enters the auto-create menu for automatically creating and adding design points to your parametric study. - parametric-study/design-points/auto-create/create-design-points
- Creates design points based on your settings. Choose from a list of sampling types, specify the number of samples, whether or not you want to remove existing design points, as well as upper and lower limits for your input parameters. 
- parametric-study/design-points/auto-create/export-designs
- Generates an optiSLang-compatible output file to a location of your choice, containing the details of the updated design points. 
- parametric-study/design-points/auto-create/get-number-of-designs
- Computes the number of designs of experiments, based on the sampling type designation and the number of levels. 
- parametric-study/design-points/auto-create/go-to-optislang
- Creates a copy of the optiSLang project from the simulation directory ( - *.opf), places it inside your working directory (as designated in the Fluent Launcher, and opens the copied project in optiSLang.
- parametric-study/design-points/auto-create/list-current-settings
- Lists the current settings for the automatically generated design points (for example, samping type, number of levels,number of samples, etc.). 
- parametric-study/design-points/auto-create/open-designs-in-optislang-postprocessor
- Opens the optiSLang postprocessor using a generated optiSLang-compatible output file (located, by default, under the current simulation directory) containing the details of the updated design points. 
- parametric-study/design-points/auto-create/print-to-console/
- Enters the print-to-console menu where you can manage settings for automatically creating design points for your parametric study. - parametric-study/design-points/auto-create/print-to-console/delete-existing-design-points?
- Prints the current value of the setting. 
- parametric-study/design-points/auto-create/print-to-console/number-of-levels
- Prints the current value of the setting. 
- parametric-study/design-points/auto-create/print-to-console/number-of-samples
- Prints the current value of the setting. 
- parametric-study/design-points/auto-create/print-to-console/range-of-input-parameter
- Prints the current range of the specified input parameter 
- parametric-study/design-points/auto-create/print-to-console/sampling-type
- Prints the current value of the setting. 
 
 - parametric-study/design-points/auto-create/optimize/
- Enter the optimization menu where you can set optiSLang-specific optimization methods and their various properties. - parametric-study/design-points/auto-create/optimize/print-to-console/
- Enters the print-to-console menu where you can manage settings for automatically creating optimized design points for your parametric study. - parametric-study/design-points/auto-create/optimize/print-to-console/active-and-inactive
- Prints the currently active and inactive design points. 
- parametric-study/design-points/auto-create/optimize/print-to-console/algorithm
- Prints the current optimization algorithm. 
- parametric-study/design-points/auto-create/optimize/print-to-console/algorithm-settings/
- Enters the menu that controls the printing of your optimization algorithm settings to the console. - parametric-study/design-points/auto-create/optimize/print-to-console/algorithm-settings/consider-failed-designs
- Prints the value of the Consider Failed Designs field. 
- parametric-study/design-points/auto-create/optimize/print-to-console/algorithm-settings/iteration-number-of-samples
- Prints the value of the iteration-based Number of Samples field. 
- parametric-study/design-points/auto-create/optimize/print-to-console/algorithm-settings/iteration-sampling-type
- Prints the value of the iteration-based Sampling Type field. 
- parametric-study/design-points/auto-create/optimize/print-to-console/algorithm-settings/max-iterations
- Prints the value of the convergence criteria-based Maximum Iterations field. 
- parametric-study/design-points/auto-create/optimize/print-to-console/algorithm-settings/max-number-of-samples
- Prints the value of the Maximum Number of Samples field. 
- parametric-study/design-points/auto-create/optimize/print-to-console/algorithm-settings/refinement-number-of-samples
- Prints the value of the refinement-based Number of Samples field. 
- parametric-study/design-points/auto-create/optimize/print-to-console/algorithm-settings/refinement-sampling-type
- Prints the value of the refinement-based Sampling Type field. 
- parametric-study/design-points/auto-create/optimize/print-to-console/algorithm-settings/refinement-type
- Prints the value of the Refinement Type field. 
- parametric-study/design-points/auto-create/optimize/print-to-console/algorithm-settings/stagnation-iterations
- Prints the value of the convergence criteria-based Stagnation Iterations field. 
- parametric-study/design-points/auto-create/optimize/print-to-console/algorithm-settings/target-cop
- Prints the value of the convergence criteria-based Target CoP field. 
 
- parametric-study/design-points/auto-create/optimize/print-to-console/criteria
- Prints the current criteria that have been defined. 
- parametric-study/design-points/auto-create/optimize/print-to-console/results-csv-path
- Prints the current file name and location of the CSV file that contains the results of the optimized parametric study. 
 
- parametric-study/design-points/auto-create/optimize/run-optimization
- Prints a summary of your current optimization settings, prompting you to confirm whether or not you want to run the optimization with the current settings. 
- parametric-study/design-points/auto-create/optimize/set/
- Enters the menu where you can set your optimization properties. - parametric-study/design-points/auto-create/optimize/set/algorithm
- Specify the optimization algorithm. 
- parametric-study/design-points/auto-create/optimize/set/algorithm-settings/
- Enter the menu for setting specific optimization algorithm properties. - parametric-study/design-points/auto-create/optimize/set/algorithm-settings/consider-failed-designs
- Sets the value of the Consider Failed Designs field. 
- parametric-study/design-points/auto-create/optimize/set/algorithm-settings/iteration-number-of-samples/levels
- Sets the value of the iteration-based Nunber of Samples/Levels field. 
- parametric-study/design-points/auto-create/optimize/set/algorithm-settings/iteration-sampling-type
- Sets the value of the iteration-based Sampling Type field. 
- parametric-study/design-points/auto-create/optimize/set/algorithm-settings/max-iterations
- Sets the value of the convergence criteria-based Maximum Iterations field. 
- parametric-study/design-points/auto-create/optimize/set/algorithm-settings/max-number-of-samples
- Sets the value of the settings-based Maximum Number of Samples field. 
- parametric-study/design-points/auto-create/optimize/set/algorithm-settings/refinement-number-of-samples
- Sets the value of the refinement-based Number of Samples field. 
- parametric-study/design-points/auto-create/optimize/set/algorithm-settings/refinement-sampling-type
- Sets the value of the refinement-based Sampling Type field. 
- parametric-study/design-points/auto-create/optimize/set/algorithm-settings/refinement-type
- Sets the value of the settings-based Refinement Type field. 
- parametric-study/design-points/auto-create/optimize/set/algorithm-settings/target-cop
- Sets the value of the convergence criteria-based Target CoP field. 
 
- parametric-study/design-points/auto-create/optimize/set/criteria
- Specify a criteria to add, delete, or edit for your optimization study. 
- parametric-study/design-points/auto-create/optimize/set/lower-and-upper-bounds
- Specify the lower and upper bounds of your input parameters. 
- parametric-study/design-points/auto-create/optimize/set/results-csv-path
- Specify the location and file name for the CSV file that will hold the results of your optimization study. 
- parametric-study/design-points/auto-create/optimize/set/set-parameter-as-active-or-inactive
- Specify the value of your input parameters and whether or not they will be active or inactive. 
 
 
 
- parametric-study/design-points/clear-data-and-edit-values
- Removes the data of a designated design point, allowing you to reset the design point and enter new information. 
- parametric-study/design-point/concurrent
- Enters the concurrent menu for parametric design points. - parametric-study/design-point/concurrent/abort-all-design-points
- Stops the concurrent update of all design points. 
- parametric-study/design-point/concurrent/abort-design-point
- Stops the concurrent update of the design point. 
- parametric-study/design-point/concurrent/refresh-status
- Refreshes the status of the design points that are being updated in the session, if any. 
 
- parametric-study/design-points/delete
- Removes the design point from the parametric study. 
- parametric-study/design-points/duplicate
- Creates a copy of a specified design point. 
- parametric-study/design-points/load-case-data-for-current-dp
- Takes the case data for the current design point and loads the data into Fluent. 
- parametric-study/design-points/print-to-console/
- Enters the print-to-console menu for the design points of your parametric study. - parametric-study/design-points/print-to-console/capture-simulation-report-data
- Prints the value for the Capture Simulation Report Data setting for the design point, where this field determines whether or not design point data is captured for the simulation report. 
- parametric-study/design-points/print-to-console/current-dp
- Prints the "current" design point. 
- parametric-study/design-points/print-to-console/input-parameters-of-dp
- Prints the value(s) for the input parameters of a design point. 
- parametric-study/design-points/print-to-console/output-parameters-of-dp
- Prints the value(s) for the output parameters of a design point. 
- parametric-study/design-points/print-to-console/status-of-all-dps
- Prints the status for all design points in the study. 
- parametric-study/design-points/print-to-console/status-of-dp
- Prints the status for the current design point in the study. 
- parametric-study/design-points/print-to-console/write-data
- Prints the value for the Write Data setting for the design point (where the Write Data field determines how a design point writes its data upon update). 
 
- parametric-study/design-points/save-journals
- Allows you to save the journal files for all design points that are currently in a "Needs Update" state. 
- parametric-study/design-points/set/
- Enter the set menu for the design points of your parametric study. - parametric-study/design-points/set/capture-simulation-report-data
- Sets the value for the Capture Simulation Report Data setting for the design point, where this field determines whether or not design point data is captured for the simulation report. 
- parametric-study/design-points/set/current-dp
- Sets the designated design point to be "current." 
- parametric-study/design-points/set/input-parameters-of-dp
- Sets the value(s) of the input parameters for a design point. 
- parametric-study/design-points/set/write-data
- Sets the value for the Write Data setting for the design point (where the Write Data field determines how a design point writes its data upon update). 
 
- parametric-study/design-points/table/
- Enter the table menu for the design points of your parametric study. - parametric-study/design-points/table/export-design-table
- Export the contents of your design point table to an external - .csvfile.
- parametric-study/design-points/table/import-design-table
- Import the contents for your design point table from an external - .csvfile.
 
 
- parametric-study/study/
- Enter the study menu for a parametric analysis. If a parametric study has yet to be defined, then only the - initializetext command is available. Once a study is initialized, then additional parametric commands become available to use.- parametric-study/study/delete
- Removes a specified parametric study. 
- parametric-study/study/duplicate
- Creates a copy of a specified parametric study. 
- parametric-study/study/initialize
- Initializes and starts the parametric study using the current case and/or data files to set up the supporting files and structures for the associated parametric project. 
- parametric-study/study/list
- Prints a listing of the available studies. 
- parametric-study/study/rename
- Allows you to assign a new name for a specified study. 
- parametric-study/study/set-as-current
- Allows you to set a specified study as the "current" study. 
- parametric-study/study/use-base-data
- Assigns the data of a specified study to use the data from the base case of the original study. 
- parametric-study/study/use-data-of-previous-dp
- Assigns the data from a previously updated design point. 
 
- parametric-study/update/
- Enter the update menu for a parametric study where you can control how to update your design points. - parametric-study/update/auto-update-mesh-morphs
- Automatically executes any configured mesh morphing definitions that are specified. This command is available if there are any defined input parameters attached to mesh morphing definitions. When invoked, Fluent executes the mesh morphing operation(s) after updating the parameter values and before solution initialization. 
- parametric-study/update/concurrent/
- Enter the concurrent menu for updating your parametric study. - parametric-study/update/concurrent/delete-endpoint
- Removes the end point of the concurrent update of all design points. 
- parametric-study/update/concurrent/licensing/
- Enter the licensing menu for concurrently updating the parametric study. - parametric-study/update/concurrent/licensing/print-to-console/
- parametric-study/update/concurrent/licensing/print-to-console/license-type
- Prints the current license type. 
- parametric-study/update/concurrent/licensing/print-to-console/optislang-license-count
- Prints the number of optiSLang licenses. 
- parametric-study/update/concurrent/licensing/print-to-console/license-optislang-license-type
- Prints the type optiSLang license. 
 
- parametric-study/update/concurrent/licensing/set/
- Enter the settings menu for licensing options when updating your concurrent parametric study. - parametric-study/update/concurrent/licensing/set/license-type
- Sets the license type for the concurrent parametric study. Choices include - "Solver License"or- "HPC Parametric".
- parametric-study/update/concurrent/licensing/set/optislang-license-count
- Sets the number of optiSLang licenses. 
- parametric-study/update/concurrent/licensing/set/license-optislang-license-type
- Sets the type of optiSLang license. Choices include - "None",- "Premium", or- "Enterprise". Using- "None"initiates standard HPC parametric licensing.
 
 
- parametric-study/update/concurrent/print-to-console/
- Enter the print-to-console menu for updating parametric studies using concurrent design points. - parametric-study/update/concurrent/print-to-console/number-of-concurrent-dps
- Prints the number of concurrent design points to update. 
- parametric-study/update/concurrent/print-to-console/number-of-cores-per-dp
- Prints the number of cores to allocate for each design point run. 
 
- parametric-study/update/concurrent/register-new-endpoint
- Registers a new end point for parametric studies using concurrent design points. 
- parametric-study/update/concurrent/set/
- Enter the settings menu for parametric studies using concurrent design points. - parametric-study/update/concurrent/set/current-endpoint
- Sets the input URL as the current submission endpoint. 
- parametric-study/update/concurrent/set/current-queue
- Sets the queue on which the design points will be updated. 
- parametric-study/update/concurrent/set/number-of-concurrent-dps
- Sets the number of concurrent design points to update. 
- parametric-study/update/concurrent/set/number-of-cores-per-dp
- Sets the number of cores to allocate for each design point run. 
 
- parametric-study/update/print-update-method
- Prints the method used for updating the study. 
- parametric-study/update/set-update-method
- Sets the method used for updating design points. 
- parametric-study/update/update-all
- Updates all design points in the parametric study. 
- parametric-study/update/update-current
- Updates the design point set as "current" in the parametric study. 
- parametric-study/update/update-selected-design-points
- Updates a selection of design points in the parametric study.