The Trn Results tab for the Output
Control
object contains settings that specify the content
of transient results files, and the timesteps at which the files are
written. Each transient results file contains results for a particular
timestep. The transient results files are written in addition to the
full results file that will be written at the end of the transient
simulation.
The settings on the Transient Results tab are analogous to those on the Backup tab; for details, see Backup Tab.
This list box is used to select Transient Results
objects for editing or deletion. Transient Results
objects can be created or deleted with the icons that appear beside
the list box.
Only one transient results file is written at a given time regardless
of how many transient results file objects exist. Each Transient
Results
object will add information to the transient results
file for that timestep. Thus, the resulting transient results file
is a union of the data requested by all Transient Results
objects for that timestep.
See Option.
See File Compression.
When the Extra Output Variables List is selected, you can specify any variable that is not included in the results file by default. For more details, see Variables in Ansys CFX in the CFX Reference Guide.
Transient Blade Row Results settings are
available when there is at least one disturbance defined in the details
view of the Transient Blade Row Models
object.
You can control the output of variables related to the Transient Blade Row model via the following settings:
Option
Choose the level of output:
Essential
,Selected Variables
, orNone
.File Compression
Choose the level of file compression as a trade-off between file size and speed.
Output Variables List
This setting is required for the
Selected Variables
option.You can multi-select variables from a list (using the Ctrl key) to have them added to the output.
Extra Output Variables List
This setting is available for the
Essential
option.You can multi-select variables from a list (using the Ctrl key) to have them added to the output.
Data compression is based on a Fourier series. The Data Compression settings control the number of Fourier coefficients to store in the output and the portion of the simulation over which these coefficients are accumulated.
You can specify the number of Fourier coefficients to be stored in the output.
The Accumulate at Period setting controls when the Fourier Coefficients should start being accumulated. The available options are:
Moving Averages
The solver continuously accumulates and updates Fourier Coefficients during the run.
Note: Once you have specified the output for transient blade row results, there is no need to create intermediate transient results files.
For instructions on setting up and using Transient Blade Row models, see Transient Blade Row Modeling in the CFX-Solver Modeling Guide.