The minimum number of iterations the CFX-Solver will run.
The maximum number of iterations the CFX-Solver will run.
For details, see Max. Iterations in the CFX-Solver Modeling Guide.
Sets the method of time scale control for a simulation. For details, see Time Scale Control in the CFX-Solver Modeling Guide.
For steady-state simulations, and for transient blade row simulations that use the Harmonic Balance
transient method,
the following options are available:
Auto Timescale
: For details, see Auto Timescale in the CFX-Solver Modeling Guide and Automatic Time Scale Calculation in the CFX-Solver Theory Guide.Length Scale Option
Three options are available:
Conservative
,Aggressive
orSpecified Length Scale
.
Local Timescale Factor
: For details, see Local Time Scale Factor in the CFX-Solver Modeling Guide.Physical Timescale
: For details, see Physical Time Scale in the CFX-Solver Modeling Guide.
For steady-state simulations, and for transient blade row simulations that use the Harmonic Balance
transient method,
two options are available if the simulation involves a solid domain, and/or a solid within a porous domain:
Auto Timescale
Physical Timescale
When Solid Timescale is set to Auto Timescale
,
the option Solid Timescale Factor
is available. For details, see Solid Time Scale Control in the CFX-Solver Modeling Guide.