Polarization

Description

The Polarization tab in the Object Properties can be used to help set definitions for specific polarizing elements when the active row is either a Jones Matrix or Mueller Matrix object type. When the object is set to any other type, this tab will be inactive.





Once you select a Type from the drop-down menu, values can be entered in the associated text boxes to compute a Jones or Mueller Matrix definition for the selected polarizing element. Modifying values or pressing the Enter key in any of the text boxes will update the calculated matrix and preview it in the Polarization tab with the header Calculated Jones Matrix (or Calculated Mueller Matrix). Clicking Set Parameters will define the active surface with the previewed matrix and update the header to Current Jones Matrix (or Current Mueller Matrix).

When the surface parameters are modified in the Non-Sequential Component Editor, or when the Reload Surface button is clicked, the displayed matrix will be the current definition of the active surface with the header Current Jones Matrix (or Current Mueller Matrix). The displayed matrix will be replaced with the associated Calculated matrix when any text box is modified.

Parameters

Parameters Description
Type Linear Polarizer and Linear Retarder polarizing elements are supported for the Jones Matrix and Mueller Matrix.
Angle Defines either the axis of transmission (when Type is set to Linear Polarizer) or the fast axis (when Type is set to Linear Retarder).
Transmission Defines the transmission of the polarizing element on the intensity of incident rays.
Degree of Polarization Defines a depolarizing ratio that the computed matrix will have on incident polarized light. This factor is multiplied to the matrix terms M11-M33, and values of 0 to 1 (inclusive) are accepted. A value of 1 represents a matrix that outputs fully polarized light, and a value of 0 represents a matrix that outputs randomly polarized light. Only applies to Mueller Matrix surface types.
Retardance Defines the phase delay of the slow axis from the fast axis. Active only when Type is set to Linear Retarder.
Depolarize When checked, sets the Depolarize parameter to 1 in the Non-Sequential Object Editor if the Object Type is a Mueller Matrix. Sets the Depolarize parameter to 0 if unchecked. Disabled for the Jones Matrix object.
Set Parameters When clicked, this button will set the active object parameters to match the displayed preview matrix within the Polarization tab. The matrix displayed in the Polarization will have the header Current Jones Matrix (or Current Mueller Matrix).
Reload Surface When clicked, this button will set the previewed matrix to the current definition of the active object. The matrix displayed in the Polarization will have the header Current Jones Matrix (or Current Mueller Matrix).