Using Datasets to Define Transient Parameters
Some parameters for Icepak thermal boundary conditions and design settings can be assigned a transient value using a dataset. For a complete list of transient parameters, see Transient Thermal Properties Dependency. You can access the Add Dataset dialog two ways:
- Create a dataset prior to defining thermal boundary conditions or design settings by adding a design dataset. See Adding Datasets for more information.
- When defining thermal boundary conditions or design settings, enable the transient option for the parameter and define the dataset. See Defining a Dataset for Transient Parameters for more information.
Note: Datasets you have previously created are available as options in the Variation drop-down list.
Defining a Dataset for Transient Parameters
- In the boundary condition or design settings dialog box, enable the check box next to the parameter.
- Select Transient from the drop-down list and click Edit.
- In the Advanced Time Variations dialog box, select Piecewise Linear from the Time Variation Function drop-down list.
- Specify a value for S0, which is the multiplier value applied to the variable parameter defined in the piecewise linear dataset (y-axis value).
- From the Variation drop-down list. select Edit.
- In the Datasets dialog box, click Add > 1D Dataset.
- In the Add Dataset dialog box, enter a Name.
- In the Coordinates area, click the X column header and select Time and then click it again and select a unit of time.
- Click the Y column header and select a parameter category (e.g., Power) and then click it again and select a unit for the parameters (e.g., W).
- In the X and Y columns enter the values for time and the time-dependent parameter.
- Click OK to save the dataset.
- In the Datasets dialog box, click Done.