Opening Legacy Projects
HFSS cannot open projects created in Ansoft HFSS
version 8.5 or earlier. HFSS 10 files can be opened, but saving them in the current format renders them unable to be reopened in version 10.
To open a legacy project:
- Click File > Open.
- From the Look
in drop-down menu, select the location of the project. In the
folder list, double-click folders to find the one that contains the project.
- Double-click the project you want to open.
Legacy Project Translation
When you open a legacy project, virtually all of the
project's pre-processing data is translated. Solution results and Optimetrics
setup data are unavailable; however, the nominal model created for Optimetrics
is translated.
The following table contains additional notes about the translation
of legacy project information.
|
Model Geometry
|
- The translated geometry's construction history
is unavailable; therefore, the original object properties you defined
cannot be modified in the Properties window.
- For units unavailable in the older version, such as yards,
the nearest available units are used; the model will be scaled slightly
to fit the new units.
- View visualization
settings apply to the saved design. If these have been changed from the
default (15 deg), this affects the memory and CPU required to open the
project.
|
|
Excitations and Boundaries
|
- If the legacy project contained
both port impedance and calibration lines, the impedance lines are translated
to integration lines, and calibration lines are ignored. If the project contained both impedance
and terminal lines, both are translated to integration lines. The impedance lines are
ignored for Driven Terminal solutions and terminal lines are ignored
if the project is changed to a Driven Modal solution.
- Boundaries assigned to named interface selections
or rectangle selections are not translated.
- For a boundary assigned to the intersection of
two faces, a new 2D sheet object is created from the intersecting area
and assign the boundary to that object.
|
|
Hybrid Regions
|
- Radiation Boundaries with FEBI become Hybrid
Regions assigned as FEBI.
|
|
Materials
|
- Functions defined in legacy projects become project
variables; therefore, functional material properties are
translated.
- Perfect conductors become regular materials with
conductivity values of 1E30.
- Object coordinate systems are created for objects
assigned anisotropic materials in legacy projects. The coordinate system
is defined at the same origin as the global coordinate system with the
same orientation defined when the anisotropic material was assigned to
the object in the legacy project.
- Nonlinear materials from legacy projects that
have magnetic saturation values greater than zero are treated as ferrite
materials. Their properties are not modified.
|
|
Mesh Operations
|
- Mesh refinement operations performed on arbitrary
boxes in legacy projects are ignored.
- Area and volume-based mesh operations are translated
as length-based mesh operations by taking their square
roots and cube roots, respectively.
|
|
Optimetrics
|
- Setup information, including design variables,
is not supported; however, the nominal model can be translated.
- Parameterizing a translated model is limited because
geometry construction history is unavailable.
|
|
Solution Types
|
- Driven solver projects that contained terminal
lines are translated to Driven Terminal solution types.
|
|
Solution Setup
|
- Impedance-only and emissions-only
solutions are not supported; therefore, these selections
in legacy projects are ignored.
- The design's initial mesh is used for the solution.
Current meshes are not translated.
- Saving dominant-only or higher-order-only mode
S-matrix entries are not supported; therefore, these mode
selections in legacy projects are ignored.
- For frequency sweeps, the Number
of Steps value specified in the legacy project is converted
to the corresponding Step Size
value.
- The total number of requested adaptive passes
in the legacy project becomes the Maximum
Number of Passes value. For example, if you
request 3 adaptive passes, solve them, and then request 2 adaptive passes,
5 will be the value specified for the Maximum
Number of Passes.
|
|
Solutions
|
- Solution data is not translated; therefore, you
must solve legacy projects again.
|
Note:
Legacy Circuit (Serenade) projects (.ssp extension) do not open correctly from
the File Open dialog box. Contact Ansys Technical
Support for assistance in converting legacy projects. Opening
an Ansys Neutral File project (.anf suffix) begins with a conversion
dialog box. See Importing ANF Design Data.