OIF CEI-112G-LR-PAM4

AEDT/SPISim COM 3.40 Settings converted from COM_CEI-112G-LR-PAM4.cfg

OP_IO_CTRL
Parameter Setting Units Information
COM Pass threshold 3 DB  
       
TABLE_93A1
Parameter Setting Units Information
f_b 36 # 36 ~ 58 GBD  
f_min 0.05 GHZ  
Delta_f 0.01 GHZ  
C_d 0.00012 NF [TX RX]
L_s 0.12 NH [TX RX]
C_b 0.00003 NF [TX RX]
z_p (TX) [12 31] MM [test cases]
z_p (RX) [12 29; 1.8 1.8] MM [test cases]
C_p 0.000087 NF [TX RX]
R_0 50 OHM  
R_d 50 OHM [TX RX] or selected
A_v 0.413 V tdr selected
A_fe 0.413 V tdr selected
A_ne 0.608 V tdr selected
L 4 NA PAM4=4, NRZ=2
M 32 NA  
DER_0 0.0001 NA  
       
TABLE_93A3
Parameter Setting Units Information
package_tl_tau 0.006141 NSMM  
package_tl_gamma0_a1_a2 [9.909E-4 2.772E-4] NSMM  
package_Z_c [87.5 92.5] OHM  
       
TABLE_9212
Parameter Setting Units Information
       
TDR_ERL
Parameter Setting Units Information
beta_x 0 NA  
rho_x 0.618 NA  
N 3500 NA  
       
ICN_PARAM
Parameter Setting Units Information
       
FILTER_EQ
Parameter Setting Units Information
f_r 0.75 FB Multiplier for Rx
c(0) 0.5 NA min
c(-3) [-0.06:0.02:0] NA [min:step:max]
c(-2) [0:0.02:0.12] NA [min:step:max]
c(-1) [-0.34:0.02:0] NA [min:step:max]
c(1) [-0.2:0.02:0] NA [min:step:max]
g_DC [-20:1:-2] DB [min:step:max]
g_DC_HP [-6:1:0] NA [min:step:max]
f_z F_B/2.5 GHZ  
f_p1 F_B/2.5 GHZ  
f_p2 F_B GHZ  
f_HP_PZ F_B/80 GHZ  
N_b 12 UI  
b_max(1) 0.85 NA  
b_min(1) 0.3 NA  
b_max(2..N_b) [0.3 0.2] NA  
b_min(2..N_b) [0.05 -0.03] NA  
       
NOISE_JITTER
Parameter Setting Units Information
R_LM 0.95 NA  
SNR_TX 33 DB tdr selected
sigma_RJ 0.01 UI  
A_DD 0.02 UI  
eta_0 8.2E-09 V2GHZ  
       
RCV_NONSTD
Parameter Setting Units Information
T_r 0.531 NS  
       
FLOATING_TAPS
Parameter Setting Units Information
N_bg 3 NA 0, 1, 2 ... Nbg groups
N_bf 3 UI taps per group (UI)
N_f 40 NA UI span for floating taps, fixed included
N_f 0.05 NA UI span for floating taps, fixed included
B_float_RSS_MAX 0.02 NA RSS tail tap limit
N_tail_start 25 UI UI start for tail tap RSS limit
       
RX_FFE
Parameter Setting Units Information
       
Other Settings
Parameter Setting Units Information