ScrSetRefineDcSimulation

Activates or deactivates adaptive mesh refinement during DC IR drop simulations.

UI Command:   Simulation > Compute DC IR. Click Other Solver Options > DC Advanced. Select or deselect Perform Adaptive Mesh Refinement.
Syntax:   obj.ScrSetRefineDcSimulation(<refine>)
Parameters:  

INT refine (0 = deselect refinement; 1 = select refinement)

Return Value:  

None.

VB Example:  

obj.ScrSetRefineDcSimulation(1)

IPY Example:  