Basis Functions in Q3D Extractor
Piecewise-constant basis functions are used for the method of moments solutions (capacitance, DC and AC inductance).
Piecewise-quadratic basis functions are used for the DC conduction solution (DC resistance). These have one unknown value at each vertex of a tetrahedron, and one unknown at the center of every tetrahedron edge.