Vent Data for General DC Machines
By option, you can insert or remove Vent data for general DC machines. If you have inserted a Vent, the icon appears under the rotor winding in the project tree.
To insert a vent:
- Right-click on the rotor icon to display the pop-up menu.
- Click Insert Vent.
To remove an existing vent:
- Right-click on the Stator icon to display the pop-up menu.
- Click Remove Vent.
The Vent Data Properties window contains the following fields.
Vent Ducts |
Number of radial vent ducts |
Duct Width |
Width of radial vent ducts |
Magnetic Spacer Width |
Width of magnetic spacer which hold vent ducts. 0 for non-magnetic spacer. |
Duct Pitch |
Vent ducts |
Holes per Row |
Number of axial vent holes per row |
Inner Hole Diameter |
Diameter of vent holes in inner row. |
Outer Hole Diameter |
Diameter of vent holes in outer row. |
Inner Hole Location |
Center-to-center diameter of inner row hole vents. |
Outer Hole Location |
Center-to-center diameter of outer row hole vents. |
Banding Slots |
Number of axial banding slots to tight the rotor winding. |
Width of Banding Slots |
Width of axial banding slots |
Depth of Banding Slots |
Depth of axial banding slots |