Setting Up Analysis Parameters for a General DC Machine
To define the solution data:
- To open the Solution Setup window, right-click Analysis in the project tree, and click Add Solution Setup.
- Click the General tab. The Operation Type is automatically set to Motor for this machine type.
- Select the Load Type
used in the motor from the following options:
Const Speed
The speed remains constant in the motor.
Const Power
Const Torque
The torque remains constant regardless of the speed. In this case, Tload = Trated, given by the output power divided by the given rated speed.
Linear Torque
The torque increases linearly with speed. In this case, Tload = Trated * (n/nrated) where Trated is given by the output power divided by the given rated speed.
Fan Load
The load varies nonlinearly with speed. In this case, Tload = Trated * (n/nrated)2 where Trated is given by the output power divided by the given rated speed.
- Enter the output power in the Rated Output Power field.
- Enter the applied or output rated DC voltage in the Rated Voltage field.
- Enter the given rated speed in the Rated Speed field.
- Enter the temperature at which the system functions in the Operating Temperature field.
- Click the DC Machine tab.
- Select one of the following from the Field Exciting Type drop-down menu:
- Separately Excited
- Self Excited
- Enter the Exciting Voltage, and select the units.
- Enter the Series Resistance, and select the units.
- To automatically obtained the Exciting Voltage and Series Resistance via the Rated Speed, rather than entering their values, then select the Determined by Rated Speed check box.
- Click OK to close the Solution Setup window.
Related Topics
Solution Data for General DC Machines