Set Default Boundary/Excitation Base Name
When setting boundaries and excitations on multiple selected surfaces, separate boundary or excitation definitions may be made automatically. Individual entries in the Project Tree will be identified with a Base Name and assigned a sequential numerical value appended to the base name.
The Set Default Boundary/Excitation Base Name dialog allows the base names for all boundary and excitation type to be specified for the current project. To set the base name for a boundary or excitation type:
- Scroll the table to the boundary or excitation of interest.
- Select the value in the Default Name column in the row of interest and enter the new base name.
- Click OK to accept the changes and dismiss the dialog box.
All base names may be reset to the factory default list by clicking Revert All, or individuals may be reset by first selecting the Default Name to be reset and clicking the Revert Selected button.