Saving Field Solutions for a Tuning Analysis

In order to preserve disk space, by default Maxwell does not save field solution data for every design variation solved in a tuning analysis. It only saves the field solutions for the nominal design when an adaptive analysis is specified in the solution setup or when you request that fields be saved for each solved point in a frequency sweep. If the nominal design is not included in the tuning analysis, all field solutions are deleted.

To save the fields for all design variations solved during a tuning analysis:

In the Tuning dialog box, select Save Fields.

Maxwell will save the field solution data for every solved design variation in a tuning analysis.

Related Topics 