Saving Field Solutions for a Parametric Setup
In order to preserve disk space, by default Maxwell does not save field solution data for every solved design variation in a parametric setup. It only saves the field solutions for the nominal design. If the nominal design is not included in the parametric setup, by default field solutions will not be available.
To save the fields for all design variations solved during a parametric analysis:
- Either Add Sweep or right-click on an existing sweep to open the Setup Sweep Analysis window.
- Select the Options tab.
- Click the Save Fields And Mesh check box.Optionally, select Copy geometrically equivalent meshes and choose whether to Solve with copied meshes only, or to Solve with copied meshes and continue adaptive passes
Maxwell will save the field solution data for every solved design variation in the parametric setup.