Near Field Coupling between Maxwell and HFSS
The purpose of this coupling is to allow Maxwell 3D frequency domain solution magnetic fields to be used as a near field source in the coupled HFSS design at exactly matched frequency.
Note: There is no Far
Field Wave coupling datalink between HFSS and Maxwell.
The suggested sequence of steps to create the link between Maxwell and HFSS is as follows.
- Create and solve the Maxwell 3D frequency domain application at the chosen frequency.
- Create the HFSS model.
- Add "mapping" object to HFSS model.
- Select all faces of the mapping object and apply a radiation boundary:
- check the Advanced Options check box.
- select the Enforced field radio button.
- Click HFSS > Excitations > Assign > Incident Wave > Near Field Wave.
The Incident Wave wizard appears. In the wizard:
- Enter a name for the source or accept the default name and click Next;
- In the Incident Wave Source: Near Field Wave Options dialog:
- Leave the translation and rotation data fields at their default zeros if the objects in the coupled designs have the desired location / orientation or change the values as needed.
- Click the Setup Link button to specify the location of the source, Maxwell design.
- Select OK to exit the Setup Link dialog.
- Select Finish to finalize the Near Field link setup.
Note: You can change
the location of the source design origin and orientation (rotation) to
perform different HFSS simulations without re-solving the Maxwell
design.