Radiation Hazards MIL STD461C ICNIRP Example

Description - This example shows how to calculate Radiation Hazards due to the radiation of two antennas placed on a ship. The limit for HERE (Hazards of Electromagnetic Radiation to Equipment) according to MIL-STD-461C is represented by an isosurface of 20V/m isosurface. Inside the volume of this isosurface no equipment shall be installed.

The HERP (Hazards of Electromagnetic Radiation to Personnel) level of 28V/m according to ICNIRP is also created. A post-processing variable "Tx_Power" control the antenna Tx power.

The project includes a Field Overlay for the Hazards of Electromagnetic Radiation to Equipment.

It also includes a Field Overlay for Hazards of Electromagnetic Radiation to Personnel.