Planar EM Setup: Advanced Tab
Click the Advanced tab of the Add HFSS 3D Layout Solution Setup window to access the following settings.
- Form polygon unions before meshing: specifies whether all objects are combined or “unioned” before meshing takes place. This can simplify the mesh; it can, however, also remove internal boundaries that may be desirable. “Unioning” is a complex operation and sensitive to almost coincident edges; it some instances, a union may produce undesirable results. Inspecting the mesh is a simple way to verify the operation.
- Use polygon defeaturing: removes very
close points, points that don't contribute to the geometry of an edge
(e.g., collinear), and very thin intrusions. When used with “unioning”,
it can be helpful in healing geometry that isn't snapped together.
- Tolerance as a ratio of the data exent: tolerance value specified as a ratio of the overall data extent; this value must necessarily be very small.
- Absolute distance: tolerance specified as an absolute value (e.g., 0.0001mm).
- Model using a wirebond: vias are modeled with a line segment.
- Mesh as a 3D via: vias are modeled using rectangles to form a 3D ribbon or solid.
- Number of sides: number of sides to use when creating the 3D representation; if less than 3, the via is modeled as a flat ribbon.
- Via field: it may be possible to reduce
the density of via fields and model them using wirebonds without significant
loss in accuracy. A via field is defined by those vias that connect two
signal layers (without intervening geometry) and attach to connected
geometry at their upper and lower points. Vias that span multiple layers
are broken up vertically at all intersection points; and each segment
is treated independently. Two vias may be adjacent and close, but they
are not thinned if they connect to electrically separate geometry
either at their upper or lower connection points — for to do so breaks an electrical connection.
- Relative min. via spacing: defines a radius around a via; any via that falls within that radius is eliminated. The value specified is a multiple of the average via spacing (the algorithm considers the averages for all via clusters and uses the minimum average spacing). If all vias are spaced equally, then a value of 1 knocks out every other via; a value of 2 filters out 2 vias between each via.
- Via material default: when a material hasn't been specified in the padstack definition and there is no override in the properties for a via, then this setting are the material associated with the via mesh. It is initially set to copper.
Note:
From the Vias area, vias may be modeled as a simple 'wirebond' or as a 3D ribbon or solid. The values specified in the analysis setup only apply to vias that do not have specific property overrides; all properties explicitly specified for a via take precedence over these values.